PSU Calculator
Pick your CPU and GPU, tweak the rest of the build, and get a defensible power-supply size: a per-component wattage breakdown with every assumption shown, three load figures (typical gaming, full synthetic load, peak transient), and a minimum plus recommended PSU rating on the standard wattage ladder. Everything runs in your browser — nothing is uploaded.
Your result
Load vs. recommended rating
Per-component breakdown
| Component | Watts | Assumption |
|---|
Standard wattage ladder
Verdicts use the selected PSU standard. “Sweet spot” = typical gaming load lands within ±10–15% of your efficiency target.
| Rating | Typical gaming | Full load | Peak transient | Verdict |
|---|
How the PSU Calculator works
The calculator stacks three different load figures, because a power supply has to survive all of them — and they are not the same number:
- Typical gaming load. The GPU runs at its full board power (games are almost always GPU-bound), while the CPU is assumed to sit at 50% of its package power, since few games push every core to maximum. Everything else — motherboard, RAM, drives, fans, lighting — runs at its steady-state draw.
- Full load. Every component at its sustained figure: CPU at vendor TDP, GPU at board power, the rest as entered. This is what an all-core stress test plus a GPU benchmark produces, and it is the number your PSU carries for minutes to hours at a time.
- Peak transient. Modern GPUs are not steady loads — they spike. An RTX 4090 rated at 450 W has been measured pulling over 600 W in millisecond bursts; an RTX 5090 can approach double its rating. Each GPU preset carries a transient factor (peak ÷ sustained) based on published measurements, and the peak figure is CPU + other components at full plus the GPU multiplied by that factor.
Sizing then follows three rules. The minimum rating is the smallest standard size where full load stays under about 90% of the rating (full load × 1.1, rounded up the ladder). The recommended ATX 3.x rating keeps full load at or below 80% of the rating — ATX 3.x units are specified to absorb short transients well beyond their continuous rating, so sustained load is what matters. The recommended traditional rating additionally requires the peak transient to stay within roughly 90% of the rating, because a conventional unit's over-current protection has less transient headroom. None of these numbers are guesses — every watt in the breakdown table above shows exactly where it comes from.
Worked example: RTX 4070 Super + Ryzen 5 7600
Say you are building a mid-range gaming PC: a Ryzen 5 7600 (65 W), an RTX 4070 Super (220 W board power, transient factor ×1.3), two DDR5 sticks (16 W), one NVMe drive (7 W), four case fans (12 W), 8 W of RGB, 30 W for the motherboard and 10 W of other devices. The totals come out to:
- Typical gaming load: 336 W (CPU at half power, GPU at full)
- Full load: 368 W
- Peak transient: 434 W
The calculator then recommends a minimum of 450 W and a recommended 500 W for both ATX 3.x and traditional units. On a 500 W PSU, typical gaming sits at about 67% of the rating and full synthetic load at 74% — inside the band where quality units run near their efficiency peak. A 550 W unit buys a little more breathing room and slightly cooler operation; either is a sound choice. Notice that no component list anywhere says “this build needs 650 W” — that figure is usually the GPU vendor's number for the card alone paired with a top-end CPU, not a system-level calculation.
Headroom and efficiency: why the recommended size beats the minimum
PSUs are not linear devices. Efficiency curves peak around 50% load on most quality units and fall off at both ends — running a 1000 W unit at 200 W wastes real electricity, while pinning a 450 W unit at 90% for hours means hotter capacitors, louder fans and a shorter life. The recommended size is the smallest standard rating that keeps full load under 80% of the rating, which lands your typical gaming load close to the efficiency peak without buying absurd headroom. It also leaves room for the things spreadsheets forget: a future GPU upgrade, an extra drive, a capture card, or a CPU whose power limit you raised in BIOS. Headroom is cheap insurance; the recommended size is roughly one ladder step above the minimum for exactly that reason.
Common PSU sizing mistakes
- Buying the “minimum” on the GPU box. Vendor minimums are a floor for the card in a high-end system, not a system-level calculation with headroom. Treat them as the absolute bottom of the range, never the target.
- Ignoring transients on traditional PSUs. A 4090 or 5090 build on an older-style PCIe 8-pin supply can trip over-current protection during millisecond spikes even when average draw is fine. If you keep a traditional unit, size for the peak — or buy ATX 3.x.
- Oversizing “for future upgrades.” A 1600 W unit on a 400 W build runs below 25% load most of the time, where efficiency sags and you pay for capacity you will never use. Size for the build you are actually buying, plus one ladder step.
- Trusting the sticker on a no-name unit. Ratings are measured in a cool lab; cheap units derate in a warm case, and their capacitors age faster under sustained load. Buy a named model from a reputable line with a real warranty — the calculator's numbers assume the label is honest.
- Daisy-chaining PCIe cables. A card that wants two 8-pin connections should get two separate cables from the PSU, not a single daisy-chained cable. A sagging or under-fed 12V line is a classic cause of crashes that look like GPU faults.
- Measuring at the wall and getting confused. The PSU itself is only about 85–94% efficient, so wall draw is always higher than what the components actually consume. This calculator works in delivered watts; multiply by roughly 1.12 to estimate what your meter will show under load.
Related tools
Suggested
Luke Keam | techgeek.biz